Selectable TC, RTD, NTC, Ω, kΩ, mA, V, mV, or Frequency Input Configurable Universal Converter.

Whatsapp

ECUC411

4-digit digital display

Easy adjustment via the buttons on the front panel

Selectable TC, RTD, NTC, Ω, kΩ, mA, V, mV, or frequency inputs

Ambient temperature compensation

Offset feature for the input

Selectable mA, V, or frequency output

24V DC sensor power supply

Three-way isolation between input, output, and power supply

Communication via isolated ModBus RTU protocol

Key lock feature

Rail-mounted

Socket terminal connection

CE marked according to EN standards

Operating/Storage Temperature 0...50 °C / -25...70 °C
Relative Humidity Up to 80% at 31°C, then linearly decreasing to 50% at 40°C
Protection Class IP20 according to EN 60529 standard
Altitude Maximum 2000m
Input Type / Scale B (Pt30Rh-Pt6Rh) thermocouple 200...1800°C / 392...3272°F
E (NiCr-Con) thermocouple -100...900°C / -148...1652°F
J (Fe-Con) thermocouple -100...900°C / -148...1652°F
K (NiCr-Ni) thermocouple -100...1300°C / -148...2372°F
L (Fe-Con) thermocouple -100...900°C / -148...1652°F
N (NiCrSi-NiSi) thermocouple -200...1300°C / -328...2372°F
R (Pt13Rh-Pt) thermocouple 0...1700°C / 32...3092°F
S (Pt10Rh-Pt) thermocouple 0...1700°C / 32...3092°F
T (Cu-Con) thermocouple -250...300°C / -418...572°F
U (Cu-Con) thermocouple -200...400°C / -328...752°F
Pt-100 resistance thermometer -200...850°C / -328...1562°F
NTC resistance thermometer -60...150°C / -76...302°F
0-20mA, 4-20mA, 0-150mV, 0-5V, 1-5V, 0-10V, 0-550Ω, 0-10kΩ -999...9999 / -99,9...999,9 / -9,99...99,99 / -9,99...9,999
0-10kHz 0-9999
Accuracy B (Pt30Rh-Pt6Rh) thermocouple ±0.1 and ±2°C (3.6°F)
E (NiCr-Con) thermocouple ±0.1 and ±0.5°C (1°F)
J (Fe-Con) thermocouple ±0.1 and ±0.5°C (1°F)
K (NiCr-Ni) thermocouple ±0.1 and ±0.5°C (1°F)
L (Fe-Con) thermocouple ±0.1 and ±1.5°C (2.7°F)
N (NiCrSi-NiSi) thermocouple ±0.1 and ±0.5°C (1°F)
R (Pt13Rh-Pt) thermocouple ±0.1 and ±1°C (1.8°F)
S (Pt10Rh-Pt) thermocouple ±0.1 and ±1°C (1.8°F)
T (Cu-Con) thermocouple ±0.1 and ±0.5°C (1°F)
U (Cu-Con) thermocouple ±0.1 and ±0.5°C (1°F)
Pt-100 resistance thermometer ±0.1 and ±0.5°C (1°F)
NTC resistance thermometer ±0.1 and ±0.5°C (1°F)
0-20mA, 4-20mA ±0.1 and ±1 digit
0-150mV ±0.1 and ±20µV
0-5V, 1-5V, 0-10V ±0.1 and ±1 digit
0-550Ω ±0.2 and ±0.1Ω
0-10kΩ ±0.5 and ±10Ω
0-10kHz ±0.5 and ±1 digit
Input Impedance B (Pt30Rh-Pt6Rh) thermocouple: Ri > 3kΩ
E (NiCr-Con) thermocouple: Ri > 3kΩ
J (Fe-Con) thermocouple: Ri > 3kΩ
K (NiCr-Ni) thermocouple: Ri > 3kΩ
L (Fe-Con) thermocouple: Ri > 3kΩ
N (NiCrSi-NiSi) thermocouple: Ri > 3kΩ
R (Pt13Rh-Pt) thermocouple: Ri > 3kΩ
S (Pt10Rh-Pt) thermocouple: Ri > 3kΩ
T (Cu-Con) thermocouple: Ri > 3kΩ
U (Cu-Con) thermocouple: Ri > 3kΩ
Pt-100 resistance thermometer: Ri > 100kΩ
NTC resistance thermometer: Ri > 100kΩ
0-20mA, 4-20mA: Ri > 50Ω
0-150mV: Ri > 3kΩ
0-5V, 1-5V, 0-10V: Ri > 3kΩ
0-550Ω, 0-10kΩ: Ri > 100kΩ
0-10kHz: Ri > 10kΩ
Power Supply ECUC411-UV: 60-250V AC, 50/60HZ / 85-300V DC
ECUC411-LV: 10-30V DC/8-24V AC, 50/60Hz
Power Consumption Maximum 7VA
Line Resistance For thermocouples: maximum 100Ω, for 3-wire PT100: maximum 20Ω
A/D Converter 16 bit
D/A Converter 13 bit
Sensor Power Supply 24V DC, maximum 30mA, unregulated, short-circuit protected
Connection 2.5mm² socket terminal
EMC EN 61326-1 - 2013
Safety Requirements EN 61010-1 - 2010 (Pollution degree 2, overvoltage category II)
Outputs mA: 0-20mA DC or 4-20mA DC, ±0.5% (maximum load resistance 500Ω)
V: 0-10V DC, 0-5V DC or 1-5V DC, maximum 10mA, ±0.5% (short-circuit protection included)
Frequency: 0-50kHz, ±0.5%, 12V pulse
Enclosure Type TH 35 type rail mount
Dimensions W25xH97xD115 mm
Weight Approximately 150g (with packaging)
Enclosure Material Self-extinguishing plastics used