English
×
All rights reserved. All content and visuals used on our site
belong to Emos Group and unauthorized use is subject to legal action.
Inviva
GLC-496R GLC-496R
GLC-496R

EMOS GROUP
Innovative Technologies with Strong Solutions,
Assurance in Quality!

GLC-496R

GLC-496R PLC CPU Module: 24 VDC power supply, 9 inputs, 6 relay outputs, 3 encoder inputs (200 kHz), modular structure (273 points), Ethernet, RS232/RS485, MODBUS RTU/TCP, 196 kB memory, 20 kHz cycle, 1 analog input/output (12/14 bit), WMI connection, email, RTC, GMT Scada, USB Datalog, DIN rail mounting.

Whatsapp

GLC-496R

PLC CPU Module

24 VDC power supply

9 Channels of 24 VDC PNP inputs

6 Channels (5A @ 250 VAC) Relay Outputs

Modular design, supports up to 16 expansion modules with a maximum of 273 points

100MB ethernet port for network access

RS232 and RS485 communication ports

MODBUS RTU Master/Slave protocol support

ASCII read-write support

Floating-point operation support

196 kB program / 10 kB variable memory

Maximum 20 kHz program cycle speed

DIN RAIL mounting

3 dual-phase (A,B,Z) encoder connection options or 3 fast counter inputs (200 kHz)

1 channel 0-10 VDC / 0-20 mADC / 4-20 mADC selectable analog input (12-bit resolution)

1 channel 0-20 mADC / 0-10 VDC (with 500 Ω resistance) analog output (14-bit resolution)

PLC internet connection service (WMI)

E-MAIL sending function

MODBUS TCP Client/Server protocol support

RTC (Real-Time Clock)

GMT Scada feature

USB Datalog feature

Power Supply 24VDC (+/- 15% tolerance)
Power Consumption 3W max
Program Cycle Speed 20 kHz max
Programming Language Ladder Editor
Commands Logical, mathematical, communication, fast counter and pulse outputs, time and counting relays, special function blocks
Certification CE marked
Ethernet Port 100MB ethernet port, for program upload and linking
Mini USB Port For program upload and linking
RS-232 Port Serial port, 4800..115200 baud rate range, supports ASCII and ModBUS RTU protocols
RS-485 Port Serial port, 4800..115200 baud rate range, supports ASCII and ModBUS RTU protocols
Digital Inputs 9 channels, 16.5 - 26VDC PNP, 3 dual-phase (A,B,Z) encoders or 3 fast counters (200kHz) can be connected
Digital Outputs 6 Channels (5A @ 250 VAC) Relay Output
Analog Inputs 1 channel 0-10 VDC / 0-20 mADC / 4-20 mADC selectable analog input (12-bit resolution)
Analog Outputs 1 channel 0-20 mADC / 0-10 VDC (with 500 Ω resistance) analog output (14-bit resolution)
Program Memory 196kB
Variable Memory 10kB
Temperature 0°C to +50°C (Without condensation)
Humidity 5%rH to 95%rH (Without condensation)